Difference between revisions of "Nokia boot failed due to raid mirror"
From cpwiki.net

(Pushed from Themanclub.) |
|||
| Line 1: | Line 1: | ||
| − | Problem | + | ==Problem== |
| − | Errors: | + | |
| + | Nokia firewall fails to boot off a RAID pair of drives moved from another chassis. This is because the volume is deactivated when moved between systems. | ||
| + | |||
| + | '''Errors:''' | ||
Boot manager loaded. | Boot manager loaded. | ||
Entering autoboot mode. | Entering autoboot mode. | ||
| Line 9: | Line 12: | ||
boot failed | boot failed | ||
| − | Solution: | + | ==Solution== |
| + | |||
| + | === activate raid volume === | ||
| + | |||
| + | BOOTMGR[1]> '''raid''' | ||
| + | -------------------------------------------------------- | ||
| + | IPSO LSI Logic Configuration Utility | ||
| + | version : Version 0.5, June 8, 2007 | ||
| + | -------------------------------------------------------- | ||
| + | Adapter Type ............. 3 (SAS Adapter) | ||
| + | PCI Device ID ............ 0x0056 | ||
| + | Hardware Revision ID ..... 0x0004 | ||
| + | Devices in Volume ........ 0 | ||
| + | FW Version ............... (01.18.00.00) decimal | ||
| + | MPI Version of FW ........ MPI Version 1.5.13.0 | ||
| + | -------------------------------------------------------- | ||
| + | 1) Raid Options Sub-Menu | ||
| + | 2) Firmware operations | ||
| + | q) EXIT | ||
| + | -------------------------------------------------------- | ||
| + | |||
| + | Choose an option: '''1''' | ||
| + | ------------------- RAID MENU -------------------------- | ||
| + | 1) Show volume(s) | ||
| + | 2) Show physical disk(s) | ||
| + | 3) Get Volume Status | ||
| + | |||
| + | Options below available from boot manager | ||
| + | ----------------------------------------- | ||
| + | 10) Disable volume | ||
| + | 11) Enable volume | ||
| + | 12) Deactivate volume | ||
| + | 13) Activate volume | ||
| + | 30) Create RAID Volume | ||
| + | 31) Delete RAID Volume | ||
| + | q) Main Menu | ||
| + | -------------------------------------------------------- | ||
| + | Choose an option: '''13''' | ||
| + | Volume: [0-1 or RETURN to quit] 0 | ||
| + | <br> | ||
| + | Volume 0 is being activated | ||
| + | <br> | ||
| + | Changes made, doing a camcontrol rescan | ||
| + | Re-scan of bus 0 was successful | ||
| + | Re-scan of bus 0 was successful | ||
| + | Waiting 5 seconds for SCSI devices to settle ...... done | ||
| + | ------------------- RAID MENU -------------------------- | ||
| + | 1) Show volume(s) | ||
| + | 2) Show physical disk(s) | ||
| + | 3) Get Volume Status | ||
| + | |||
| + | Options below available from boot manager | ||
| + | ----------------------------------------- | ||
| + | 10) Disable volume | ||
| + | 11) Enable volume | ||
| + | 12) Deactivate volume | ||
| + | 13) Activate volume | ||
| + | 30) Create RAID Volume | ||
| + | 31) Delete RAID Volume | ||
| + | q) Main Menu | ||
| + | -------------------------------------------------------- | ||
| + | <br> | ||
| + | Choose an option: '''1''' | ||
| + | ------------------ Show Volumes ------------------------ | ||
| + | 1 volume is active, 2 physical disks are active | ||
| + | <br> | ||
| + | Volume 0 is Bus 0 Target 0, Type IM (Integrated Mirroring) | ||
| + | Volume State: degraded, enabled, resync in progress | ||
| + | Volume Settings: write caching enabled, auto configure | ||
| + | Volume draws from Hot Spare Pools: 0 | ||
| + | Volume Size 76158 MB, Stripe Size 0 KB, 2 Members | ||
| + | Primary is PhysDisk 0 (Bus 0 Target 4) | ||
| + | Secondary is PhysDisk 1 (Bus 0 Target 1) | ||
| + | <br> | ||
| + | ------------------- RAID MENU -------------------------- | ||
| + | 1) Show volume(s) | ||
| + | 2) Show physical disk(s) | ||
| + | 3) Get Volume Status | ||
| + | <br> | ||
| + | Options below available from boot manager | ||
| + | ----------------------------------------- | ||
| + | 10) Disable volume | ||
| + | 11) Enable volume | ||
| + | 12) Deactivate volume | ||
| + | 13) Activate volume | ||
| + | 30) Create RAID Volume | ||
| + | 31) Delete RAID Volume | ||
| + | q) Main Menu | ||
| + | -------------------------------------------------------- | ||
| + | Choose an option: '''q''' | ||
| + | -------------------------------------------------------- | ||
| + | 1) Raid Options Sub-Menu | ||
| + | 2) Firmware operations | ||
| + | q) EXIT | ||
| + | -------------------------------------------------------- | ||
| + | <br> | ||
| + | Choose an option: '''q''' | ||
| + | Re-scan of bus 0 was successful | ||
| + | Re-scan of bus 0 was successful | ||
| + | Waiting 5 seconds for SCSI devices to settle .. | ||
| + | Type 'boot <enter>' to continue boot process .. | ||
Revision as of 03:03, 20 September 2014
Problem
Nokia firewall fails to boot off a RAID pair of drives moved from another chassis. This is because the volume is deactivated when moved between systems.
Errors: Boot manager loaded. Entering autoboot mode. Type any character to enter command mode. Error: /image on /dev/mirror/gmroots1f
does not exist or is not a file
umount: /mnt: not a file system root directory boot failed
Solution
activate raid volume
BOOTMGR[1]> raid -------------------------------------------------------- IPSO LSI Logic Configuration Utility version : Version 0.5, June 8, 2007 -------------------------------------------------------- Adapter Type ............. 3 (SAS Adapter) PCI Device ID ............ 0x0056 Hardware Revision ID ..... 0x0004 Devices in Volume ........ 0 FW Version ............... (01.18.00.00) decimal MPI Version of FW ........ MPI Version 1.5.13.0 -------------------------------------------------------- 1) Raid Options Sub-Menu 2) Firmware operations q) EXIT --------------------------------------------------------
Choose an option: 1 ------------------- RAID MENU -------------------------- 1) Show volume(s) 2) Show physical disk(s) 3) Get Volume Status
Options below available from boot manager ----------------------------------------- 10) Disable volume 11) Enable volume 12) Deactivate volume 13) Activate volume 30) Create RAID Volume 31) Delete RAID Volume q) Main Menu -------------------------------------------------------- Choose an option: 13 Volume: [0-1 or RETURN to quit] 0
Volume 0 is being activated
Changes made, doing a camcontrol rescan Re-scan of bus 0 was successful Re-scan of bus 0 was successful Waiting 5 seconds for SCSI devices to settle ...... done ------------------- RAID MENU -------------------------- 1) Show volume(s) 2) Show physical disk(s) 3) Get Volume Status
Options below available from boot manager ----------------------------------------- 10) Disable volume 11) Enable volume 12) Deactivate volume 13) Activate volume 30) Create RAID Volume 31) Delete RAID Volume q) Main Menu --------------------------------------------------------
Choose an option: 1 ------------------ Show Volumes ------------------------ 1 volume is active, 2 physical disks are active
Volume 0 is Bus 0 Target 0, Type IM (Integrated Mirroring) Volume State: degraded, enabled, resync in progress Volume Settings: write caching enabled, auto configure Volume draws from Hot Spare Pools: 0 Volume Size 76158 MB, Stripe Size 0 KB, 2 Members Primary is PhysDisk 0 (Bus 0 Target 4) Secondary is PhysDisk 1 (Bus 0 Target 1)
------------------- RAID MENU -------------------------- 1) Show volume(s) 2) Show physical disk(s) 3) Get Volume Status
Options below available from boot manager ----------------------------------------- 10) Disable volume 11) Enable volume 12) Deactivate volume 13) Activate volume 30) Create RAID Volume 31) Delete RAID Volume q) Main Menu -------------------------------------------------------- Choose an option: q -------------------------------------------------------- 1) Raid Options Sub-Menu 2) Firmware operations q) EXIT --------------------------------------------------------
Choose an option: q Re-scan of bus 0 was successful Re-scan of bus 0 was successful Waiting 5 seconds for SCSI devices to settle .. Type 'boot <enter>' to continue boot process ..